The objective of the present work is to present the state of the investigations carried out on the devices of Stainless Steel 316 (AI 316) used in the surgical procedures for the replacement of the hip joint, through the analysis of articles disclosed in publications included in journals of the Science Direct, PubMed, Scielo and Redalyc databases. The selection criteria for the search and selection of potentially relevant articles were defined, placed in a collection format to facilitate their registration and analysis. A total of 17 publications met the required criteria. The results show that the publications of experimental design have shown a lower growth compared to other types of designs, among which descriptive or exploratory studies prevail, which mostly report the undesirable effects present in patients after surgery. This aspect has led to modifications to these devices, in order to reduce the morbidity of these implants.

Downloads

Download data is not yet available.

Author Biographies

Walther Zhukov Paz y Miño Intriago, Hospital Dr. Verdi Cevallos Balda. Ministry of Public Health. Ecuador

Walther Zhukov Paz y Miño Intriago

Hospital Dr. Verdi Cevallos Balda. Ministry of Public Health. Ecuador

https://orcid.org/0000-0001-5249-8718

Pablo Emilio Saltos Arteaga, Hospital Portoviejo-Ecuadorian Institute of Social Security. Ecuador

Pablo Emilio Saltos Arteaga

Hospital Portoviejo-Ecuadorian Institute of Social Security. Ecuador

Paul Mauricio Sánchez Cabrera, Hospital Dr. Verdi Cevallos Balda. Ministry of Public Health. Ecuador

Paul Mauricio Sánchez Cabrera

Hospital Dr. Verdi Cevallos Balda. Ministerio de Salud Pública. Ecuador

Carlos Alberto Bermúdez Solórzano, Hospital Dr. Verdi Cevallos Balda. Ministry of Public Health. Ecuador

Carlos Alberto Bermúdez Solórzano

Hospital Dr. Verdi Cevallos Balda. Ministry of Public Health. Ecuador

References

Aranda-Villalobos P., Fernández C., Navarro-Espigares J., Hernández-Torres E., Villalobos M., Arendt-Nielsen L., & Arroyo M. (2013). Normalization of widespread pressure pain hypersensitivity after total hip replacement in patients with hip osteoarthritis is associated with clinical and functional improvements.
Arthritis Rheum, 65: 1262-1270. 153 Arash V., Keikhaee F., Rabiee S., Rajabnia R., Khafri S., & Tavanafar, S. (2016). Evaluation of antibacterial effects of silver-coated stainless steel orthodontic brackets. Journal of dentistry (Tehran, Iran), 13(1): 49–54.
Arthur W.B. (2009). The nature of technology. What it is and how it evolved. New York: Free Press.
Chan P. K., Cheung S. L., Lam K. H., Fung W. C., Chan V., Cheung A., Cheung M. H., Fu H., Yan C. H., & Chiu K. Y. (2021). Use of a modular hip dual-mobility articulation in patients with high risk of dislocation: a relatively small-sized acetabulum in Asian patients may limit its use. Arthroplasty (London, England). 3(1): 7. https://doi.org/10.1186/ s42836-020-00066-0.
Di Puccio F., & Mattei L. (2015). Biotribology of artificial hip joints. World journal of orthopedics 6(1): 77–94. https://doi.org/10.5312/wjo.v6.i1.77
Dong H., Li Z., Somani M., & Misra R. (2021). The significance of phase reversion-induced nanograined/ultrafine-grained (NG/UFG) structure on the strain hardening behavior and deformation mechanism in copper-bearing antimicrobial austenitic stainless Steel. J Mechanical Behavior of Biomedical Materials. 119: 104489. https://doi.org/10.1016/ j.jmbbm.2021.104489.
Duffo G. (2012). Materiales y materias primas. Capítulo 8-Biomateriales. Ministerio de Educación-Instituto Nacional de Educación Tecnológica. http://www.inet.edu.ar/wp-content/uploads/2012/11/ biometales.pdf.
Hartzler M., Abdel M., Sculco P., Tauton M., Pagnano M., & Hanssen A.D. (2018). Otto aufranc award: dual-mobility constructs in revision tha reduced dislocation, rerevision, and reoperation compared with large femoral heads. Clin Orthop Relat Res. 476(2): 293-301.
Harwin S., Mistry J., Chughtai M., Khlopas A., Chukwuweike G., Newman J., Higuera C., Bonutti P., Malkani A., Kolisek F., Delanois R., & Mont M. (2017). Dual Mobility Acetabular Cups in Primary Total Hip Arthroplasty in Patients at High Risk for Dislocation. Surg Technol Int, 30: 251-258.
Hoyos C. (2000). Un modelo para Investigación Documental: Guía teórico-práctica sobre construcción de estados del arte. Medellín: Señal Editora Learmonth
I., Young C., & Rorabeck C. (2007). The operation of the century: total hip replacement. Lancet, 370 (9597): 1508-1519.https://doi. org/10.1016/S0140-673 (07)60457-7
Li M., Ma Z., Zhu Y., Xia H., Yao M., Chu X., Yang K., Yang M., Zhang Y., & Maos C. (2016). Toward a molecular understanding of the antibacterial mechanism of copper-bearing titanium alloys against Staphylococcus aureus. Adv. Healthcare Mater, 5(5): 557-66. doi:10.1002/adhm.20150 0712.
National Joint Replacement Registry, Australian Orthopaedic Association. (2017). Hip, Knee & Shoulder Arthroplasty. Annual Report. 10.13140/ RG.2.2.27578.0864
Organización Mundial de la Salud. (2008). Alianza Mundial Para la seguridad del paciente. Segundo reto mundial por la seguridad del paciente. La cirugía segura salva vidas. https://who.int/patientssafety/ sssl_brochure_spanish.pdf
Park B., Lim K., Shon W., Shetty Y., & Heo K. (2019). Comparison of Functional outcomes and associated complications in patients who underwent total hip arthroplasty for femoral neck fracture in relation to their underlying medical comorbidities. Hip & Pelvis. 31(4): 232-237.
Pardo A., Merino M., Coy A., Viejo F., Arrabal R., & Matykina E. (2008). Effect of Mo and Mn additions on the corrosion behavior of AISI 304 and 316 stainless steels in H2SO4. Corrosion Science. 50: 780–794. Pereda M., Kang K., Bonetto R., Llorente C., Bilmes P., & Gervasi, C. (2012). Impact of surface treatment on the corrosion resistance of ASTM F138-F139 stainless steel for biomedical applications. Procedia Materials Science. 1: 446–55.
Raimann R., & Aguirrea D. (2021). Displasia del desarrollo de la cadera: tamizaje y manejo en el lactante. Rev Med Clin Condes. 32(3): 263-270.
Sanchez-Sotelo J., Haidukewych G., & Boberg C. (2006). Hospital cost of dislocation after primary total hip arthroplasty. J Bone Joint Surg, 88(2): 290-4.
Seisamed. (2017). Uso de acero inoxidable en equipos para hospitales. SeisaMed. https://www. seisamed.com/uso-de-acero-inoxidable-en-equipos -para- hospitales
Viladot Voegeli A. (2009). Anatomía funcional de la cadera. En: Balibrea Cantero JL, Balibrea. Traumatología.14a ed. Madrid: Marban. p. 185-194
Williams S., Bachison C., Michelson J., & Manner P. (2008). Component position in 2-incision minimally invasive total hip arthroplasty compared to standard total hip arthroplasty. J. Arthroplasty, 23: 197-202. 154 Wu C., Qu X., Liu F., Li H., Mao Y., & Zhu Z. (2014). Risk factors for periprosthetic joint infection after total hip arthroplasty and total knee arthroplasty in Chinese patients. PloS one, 9(4): e95300.
Yang T., DeLaFranier B., & Thompson M. (2021). Anti-Thrombogenicity Study of a Covalently-Attached Monolayer on Stent-Grade Stainless Steel. Materials, 14: 2342. https://doi.org/10.3390/ ma14092342. Zhang E., Zhao X., Hu J.,
Wang R., Fu S., & Qin G. (2021). Antibacterial metals and alloys for potential biomedical implants.Bioactive Materials, 6: 2569–2612.
Zhang D., Ren L., Zhang Y., Xue N., Yang K., & Zhong M. (2013). Antibacterial activity against Porphyromonas gingivalis and biological characteristics of antibacterial stainless steel. Colloids Surf. B Biointerfaces. 105: 51–57.
Zhang H., Guo S., Wang D., Zhou T., Wang L., & Ma J. (2016). Effects of nanostructured, diamondlike, carbon coating and nitrocarburizing on the frictional properties and biocompatibility of orthodontic stainless steel wires. Angle Orthod. 86 (5): 782–788.
Zhang H., Xu Z., Zhou A., Yan W., Zhao P., Huang X., & Zhang J. (2017). Efficacy of Kirschner-wires and tension band in hip arthroplasty for aged patients with unstable intertrochanteric osteoporotic fracture: A 2-to-11-year follow-up. Medicine, 96(1): e5614. https://doi.org/10.1097/ MD.0000 000000005614
Zujur D., & ÁlvarezBarreto J.F. (2016). Prótesis en artroplastia total de cadera y recubrimientos bioactivos de quitosano para mejorar su desempeño. Revista Ingeniería Biomédica. 10 (19): 33-43.
Published
2022-12-21
How to Cite
Paz y Miño Intriago, W. Z., Saltos Arteaga, P. E., Sánchez Cabrera, P. M., & Bermúdez Solórzano, C. A. (2022). HIP ARTHROPLASTY, 316 STAINLESS STEEL IMPLANTS. REDIELUZ, 12(2), 145 - 154. https://doi.org/10.5281/zenodo.7438678