Analysis of quantity and quality of water from air conditioners and itspotentialuse.

Análisis de la cantidad y calidad del agua de aire acondicionado y supotencial de uso.

  • Marcos Bitter Universidad Nacional Experimental Francisco de Miranda
  • Alberto Jiménez Universidad Nacional Experimental Francisco de Miranda
  • Ricardo Bitter Universidad Nacional Experimental Francisco de Miranda
Keywords: air conditioner water use, water availability, water quality standard

Abstract

Activities on these results, the air conditioner water can be used in domestic activities such as general cleaning, water for toilets and irrigation of plants. Air conditioner water, depending on its quality, could be used in domestic activities and cause an impact on the reduction of drinking water usage. The objective of the present work was to evaluate if the composition analysis (physicochemical and microbiological factors) of the air conditioner water, indicates that it can be considered good quality water suitable for domestic activities. The amount of water produced by air conditioner equipment (depending on its rated capacity) in a residential complex, was measured daily (at day and night intervals) for 15 continuous days. In each sample collected, ambient temperature and relative humidity were recorded. Physicochemical and microbiological parameters were analyzed for both, air conditioner water and drinking water, following the corresponding standardized protocols. Results show that 12000 BTU’s air conditioner equipment produced 1.5 L /h, the18000 BTU’s produced 2.96 L /hand those of 24000 BTU, 4.2 L /h. The physicochemical and microbiological characteristics were within the sanitary requirements of the legal regulations, which make the air conditioner water to qualify as good quality water. The results obtained for the potable water exceeded those of the air conditioner water, being the most relevant Dissolved Total Solids, Conductivity), Sulphates and CaHardness. Based on these results, the air conditioner water can be used in domestic activities such as general cleaning, water for toilets and irrigation of plants.

Downloads

Download data is not yet available.

References

AGUIRRE, S. E., N. V.PIRANEQUE y A. ROZO. 2018. Potencial de Uso del Agua proveniente de los Sistemas de Aire Acondicionado en el Caribe Seco Colombiano. Información Tecnológica, 29(6): 33-42 (en línea) (disponible en: http://dx.doi.org/10.4067/S0718-07642018000600033).

ALGARNY, S. A., C. A. SALEEL Y M. A. MUJEEBU. 2018. 2018. Air conditioning
condensate recovery and applications Current developments and challenges ahead.
Sustainable Cities and Society. 37: 263-274. (Disponible en:
https://www.researchgate.net/publication/321481002Airconditioningcondensaterecoverya
ndapplications Current developmentsandchallengesah ead).

ALFONSO GARAVITO, A. M. Y M. C. DE LA HOZ HENRÍQUEZ. 2019. Reuso de
agua de los aires acondicionados. Propuesta de producción más limpia para aprovechamiento de agua de condensación de los aires acondicionados en la Universidad
de la Costa. Trabajo de Grado para otorgar el título de Ingeniero Ambiental. Universidad de la Costa, Facultad de Ingeniería Civil y Ambiental, Ingeniería Ambiental,
Barranquilla. Colombia.

BANCO MUNDIAL. 2004. Water Resource Sector Strategy. # 28116

BITTER REY, M. E. 2017. Aplicación de Políticas Ambientales para el Manejo de Recursos Naturales y Residuos Peligrosos en laboratorio de la UCLA. Informe de Pasantía. Ciencias Ambientales, UNEFM. 58 p.

BITTER, M., L. M. MARCO, D. TORRES Y E. GÓMEZ. 2017. Reúso del Agua y
Aprovechamiento de Residuos Agroindustriales en el Laboratorio de análisis
Instrumental del Decanato de Agronomía. Bioagro (edición especial), Resúmenes XIII Jornadas de Investigación, Decanato de Agronomía – UCLA,p4.

CLARKE, K. R. Y R. N. GORLEY. 2001. Primer V5: User Manual/Tutorial. Primer –E. Ltd. Plymouth.

DECRETO N° 883. 1995. Normas para la Clasificación y el Control de la Calidad de los Cuerpos de Agua y Vertidos o Efluentes Líquidos. GACETA OFICIAL EXTRAORDINARIA: 5.021 del 18/12/95., (Venezuela).

EPA. FEDERAL GREEN CHALLENGE. 2014. Case Study: Condensate Recovery System Reduces Water Usage and Discharge. (Disponible en: https://www.epa.gov/sites/production/files/2015-05/documents/cs2-gsa-condensate- recovery.pdf).

MAGRINI, A., L. CATTANI, M. CARTESEGNA AND I. MAGNANI. 2017. Water
Production from Air Conditioning Systems: Some Evaluations about a Sustainable Use
of Resources. Sustainability. 9, 1309.

MAGRINI, A., L. EATTANI, M. CARTESEGNA AND L. MAGNANI. 2015. Integrated
systems for air conditioning and production of drinking water. Preliminary Considerations. Energy Procedia. 75: 1659 – 1665.

MSAS (MINISTERIO DE SANIDAD Y ASISTENCIA SOCIAL, VENEZUELA). 1998.
Normas Sanitarias de Calidad del Agua Potable. Numero S.G. - 018-98. Gaceta de La República de Venezuela No. 36.395, del 13/02/ 98.

NORMA 3M. 1999. Petrifilm™ Placas Alta Sensibilidad para Recuento de Coliformes. Guía de Interpretación. 3M S.A.

NOUTCHA, M. A. E., O. DAMIETE, J. J. R. MATHEW, O. NGOZI, O. U. CHINWENDUM, CHU. EZERA AND S. N. OKIWELU. 2016. Quantity and Quality of Water Condensate from Air Conditioners and Its Potential Uses at the University of Port Harcourt, Nigeria) Adv. Appl. Sci. Res. 7(6):45-48

NTE (NORMA TÉCNICA ECUATORIANA). 2015. Microbiología de Los Alimentos para Consumo Humano y Alimentación Animal. Método Horizontal para La Enumeración de Coliformes. Técnica de Recuento de Colonias. (ISO 4832:2006, IDT). NTE INENISO 4832.

OMS (ORGANIZACIÓN MUNDIAL DE LA SALUD). 2003. Guías para la Calidad de Agua Potable. Primer Apéndice Tercera Edición, Volumen 1.

PAPA FRANCISCO. 2015. Carta Encíclica Laudato Si’. Disponible en: https://www. aciprensa.com/Docum/LaudatoSi.pdf

QUISPE ANDÍA, A., K. M. CALLA VÁSQUEZ, J. S. YANGALI VICENTE, J. L.
RODRÍGUEZ LÓPEZ Y I. I. PUMACAYO PALOMINO. 2019. Estadística no paramétrica
aplicada a la investigación científica con software SPSS, MINITAB Y EXCEL. Editorial EIDEC.

SCALIZE, P. S., S. SOARES SILVA, A. C. FONSECA ALVES, T. AZEVEDO MARQUES, G. G. MARTINS MESQUITA, N. BALLAMINUT and A. C. JOÃO ALBUQUER QUE. 2018. Use of condensed water from air conditioning systems. Open Eng., 8:284–292. (En línea) (Disponible en: https://www.researchgate.net/publication327839794_Use_of_condensed_water_from_a
ir_conditioning_systems/fulltext/5ba8d768299bf13e604845fb/327839794_Use_of_ condensed_water_from_air_conditioning_systems.pdf?origin=publication_detail).

SIAM, L., I. A. AL KHATIB, F. ANAYAH, S. JODEH, G. HANBALI, B. BAYAN KHALAF AND A. ABDALHADI DEGHLES. 2019. Developing a Strategy to Recover Condensate Water from Air Conditioners in Palestine. Water 11: 1-17.

SOMANI, S. 2016. Reducing Carbon and water footprints with effective use of condensate water in hot and humid climates. Research Methods GRCS.701.30 Technical Paper. (Disponible en: https://www.google.com/search?client=firefox-b d&q=https%3A%2F%2Fwww.epa.gov%2Fsites%2Fproduction%2Ffiles%2F201505% 2Fdocuments%2Fcs2-gsa-condensate-recovery.pdf).

TECNOXPLORA. 2014. ¿Se puede utilizar para algo el agua que suelta el aire acon- dicionado? (Disponible en: http://www.tecnoxplora.com/ciencia/divulgacion/puede-uti- lizar-algo-agua-que-suelta-aire-acondicionado_2014091557fca5ef0cf2fd8cc6b0eb06. html.

UNESCO. 2019. Programa Mundial de Evaluación de los Recursos Hídricos de la UNESCO. (WWDR). Informe Mundial de las Naciones Unidas sobre el Desarrollo de los Recursos Hídricos. No dejar a nadie atrás. París, UNESCO. (Disponible en: https:// www.acnur.org/5c93e4c34.pdf).
Published
2021-04-12
How to Cite
Bitter, M., Jiménez, A., & Bitter, R. (2021). Analysis of quantity and quality of water from air conditioners and itspotentialuse.: Análisis de la cantidad y calidad del agua de aire acondicionado y supotencial de uso. Boletín Del Centro De Investigaciones Biológicas, 54(2), 125-144. Retrieved from https://produccioncientificaluz.org/index.php/boletin/article/view/35708