REVISTA DE LA UNIVERSIDAD DEL ZULIA. época. Año 13 N° 36, 2022
D. P. Guerrero-Cuasapaz et al. // Analysis of the structural behavior of flat and circular 222-240
DOI: http://dx.doi.org/10.46925//rdluz.36.15
222
Analysis of the structural behavior of flat and circular self-supporting
roof using finite elements
David Patricio Guerrero-Cuasapaz*
Milton Bolívar Guerrón-Figueroa **
José Luis Pilamunga-Guallpa***
Cristhian Daniel Páez-Redrován****
Nelson Andrés López-Machado*****
ABSTRACT
The development and innovation of Science, specifically in the branch of construction in Civil
engineering, has led the implementation of new alternatives in analysis, design and construction
of industrial buildings. For this reason, in this research it was proposed to carry out a study of
structural behavior of two types of self-supporting roofs: flat and circular, which were analyzed
using computational tools for simulation through finite elements, in which initially the structure
made up of columns, beams and steel sheets was completely modeled with an equivalent cross
section, which made up the self-supporting roofs; then only the steel sheets with real cross
section were discretized, and it was noted that in the extremes were the greatest stresses
generated by the application of horizontal and vertical loads; and the maximum displacement of
the circular roof was 14.32 % of the flat one.
KEYWORDS: Construction engineering; structural design; self-supporting roof; weight.
*Professor. Civil Engineering Department, Salesian Polytechnic University. Quito, Ecuador.
ORCID: https://orcid.org/0000-0002-8547-906X. E-mail: dguerrero@ups.edu.ec
**Professor. Civil Engineering Department, Salesian Polytechnic University. Quito, Ecuador.
ORCID: https://orcid.org/0000-0002-4136-9483
***Professor. Civil Engineering Department, Salesian Polytechnic University. Quito, Ecuador.
ORCID: https://orcid.org/0000-0002-0892-1838
****Professor. Civil Engineering Department, Salesian Polytechnic University. Quito, Ecuador.
ORCID: https://orcid.org/0000-0001-5633-6855
*****Professor. Structural and Geotechnical Engineering Department, Pontifical Catholic
University of Chile. Santiago, Chile. ORCID: https://orcid.org/0000-0002-3111-7952
Recibido: 05/10/2021 Aceptado: 01/12/2021
REVISTA DE LA UNIVERSIDAD DEL ZULIA. 3ª época. Año 13 N° 36, 2022
D. P. Guerrero-Cuasapaz et al. // Analysis of the structural behavior of flat and circular 222-240
DOI: http://dx.doi.org/10.46925//rdluz.36.15
223
Análisis del comportamiento estructural de cubierta autoportante
plana y circular utilizando elementos finitos
RESUMEN
El desarrollo e innovación de la Ciencia y específicamente dentro la rama de la construcción en
Ingeniería civil ha provocado que se implementen nuevas alternativas en análisis, diseño y
construcción de naves industriales. Por tal motivo, en la presente investigación se planteó
realizar un estudio del comportamiento estructural de dos tipos de cubiertas autoportantes:
plana y circular, las mismas que fueron analizadas utilizando herramientas computacionales
para simulación a través de elementos finitos, en las que inicialmente se modeló de forma
completa a la estructura constituida de columnas, vigas y láminas de acero con una sección
transversal equivalente, que conformaron las cubiertas autoportantes; posterior a ello se
discretizó únicamente las láminas de acero con sección transversal real, y se obser que en los
extremos fueron los mayores esfuerzos generados por la aplicación de solicitaciones horizontales
y verticales; y el desplazamiento máximo de la cubierta circular fue 14.32 % de la plana.
PALABRAS CLAVE: Ingeniería de la construcción; diseño estructural; cubierta autoportante;
peso.
Introduction
Innovation and competitiveness in the world of construction causes the manufacture of
roofs for industrial buildings to change both in their materials and their geometry. The most
used materials for the construction of sheds are wood, aluminum, and steel, which easily adapt
to various environments or climates without losing their functionality (Soria, 2020).
Industrial buildings made of structural steel provide qualities such as versatility,
implementation of new facilities, extensions, and improvements in general. Besides, this type of
structure can be designed in a plastic range in order to reduce manufacturing costs (Arnedo,
2016).
Currently, industrial buildings use self-supporting roofs which are an enclosure or
membrane-type roof that uniformly distributes the stresses received, either thermal or climatic
of any order, and distributes them on the walls in a uniform way, contributing to the distribution
of loads and their linear and uniform transmission to the foundations. As there is no supporting
structure, the roofs rest on the load-bearing beams or perimeter beams, which constitutes their
REVISTA DE LA UNIVERSIDAD DEL ZULIA. 3ª época. Año 13 N° 36, 2022
D. P. Guerrero-Cuasapaz et al. // Analysis of the structural behavior of flat and circular 222-240
DOI: http://dx.doi.org/10.46925//rdluz.36.15
224
main differential element: the total absence of purlins, trusses, beams, or any other intermediate
resistant element. These are works in which the calculation of the geometry of the structure
must be carried out with accuracy since it is not a system based on standard pieces but it is
manufactured and custom-made for each building, allowing to incorporate elements such as
isolations, translucent, which can be curved or flat (Durma, 2016).
In Ecuador, the analysis and design of industrial buildings have been pivotal for the
implementation of several projects on a national scale (Cuichán, 2016), which promote and make
the country's productive system grow; for this reason, there is a need to know the structural
behavior between a flat and circular self-supporting roof (Pilamunga, 2021; Páez, 2020); hence,
the aim of this research is to establish a comparative analysis between these types of industrial
buildings.
The application of the finite element method allows finding approximations in the
solution, since it divides the continuous medium of a domain into elements with finite
dimensions, which supports the analysis of the structural response of a system (Nápoles et al.,
2015). Regarding the application of this method, it is very useful to predict the performance and
possible failures of a specific design; consequently, it will serve to obtain structures with greater
benefits in safety, stability, and economy (Vásquez & López, 2001).
1. Materials and Methods
The main objective of this research was to carry out a comparative analysis of the
structural behavior between two flat and circular self-supporting roofs, using finite elements
with the help of computer packages to determine the roof with the best structural performance
when faced with the application of vertical and horizontal stresses.
1.1. Description of self-supporting roofs
In this research, two industrial buildings were considered that are made up of columns,
truss-type perimeter beams and steel sheets as covering of the buildings, as can be seen in figure
1; it is worth mentioning that these structures lack of main beams and purlins. The free span that
was used was 20 m, and the separation between frames depended on the useful width of which
each steel sheet is formed to create the self-supporting roof. Regarding the height of the columns
REVISTA DE LA UNIVERSIDAD DEL ZULIA. 3ª época. Año 13 N° 36, 2022
D. P. Guerrero-Cuasapaz et al. // Analysis of the structural behavior of flat and circular 222-240
DOI: http://dx.doi.org/10.46925//rdluz.36.15
225
of the sheds, they obeyed the type of shape that the roof received, i.e., both columns were raised
in the circular shed to be equal in height, i.e., 6.00 m; while on the flat roof, a minimum slope of
5 % was applied (Fernández, 1998)height of its columns had to be different, i.e., height 1 was
6.00 m and height 2 was 6.70 m.
(a)
(b)
Figure 1. Self-supporting roofs geometry: a) flat, b) circular.
1.2. Characteristics of the material used in beams, columns, and steel sheet for self-
supporting roofs
For the configuration of the truss-type columns and perimeter beams, hot-rolled profiles
were used, which had equal side angles (AISC, 2016), and cold-formed profiles type “C” or
channels (AISI, 2016); thus, in this research ASTM A36 steel was used.
For the coverage of the sheds in this research, the Imap-800 sheet (Açoport, 2021), CS
1000-610 (Sanxing, 2021) was used for flat and circular roof respectively. Each of these has a
different useful width, height and thickness recommended for the 20 m span, as shown in table
1 and figure 2.
Table 1. General characteristics of self-supporting roofs: flat and circular.
Roof type
Designation
Width
(mm)
Height
(mm)
Flat
Imap-800
800
260
Circular
CS 1000-610
610
252
REVISTA DE LA UNIVERSIDAD DEL ZULIA. 3ª época. Año 13 N° 36, 2022
D. P. Guerrero-Cuasapaz et al. // Analysis of the structural behavior of flat and circular 222-240
DOI: http://dx.doi.org/10.46925//rdluz.36.15
226
(a)
(b)
Figure 2. Steel sheets for self-supporting roofs: a) circular, b) flat.
The material used for the conformation of the self-supporting roofs comes from
galvanized steel coils that lack of paint as indicated in the regulations (ASTM A653, 2020).
Table 2 shows the technical sheet of the constituent material of the industrial buildings that
were analyzed in this research.
Table 2. Technical data sheet of the material used in self-supporting roofs: flat and circular.
Description
Flat and
circular roof
Coating designation
Z275-G90
Coating weight on both sides (g/m²)
275
Base metal density (kg/)
7850
Young’s modulus (kg/m³)
200000
Poisson’s ratio
0.3
Bulk modulus (MPa)
167000
Shear modulus (MPa)
76900
Yield stress (MPa)
380
Tensile strength (MPa)
480
Additionally, it can be indicated as part of the specific geometry of the circular self-
supporting roof that the arrow used was 4.00 m, which was determined through equations 1
(Ruiz, 2003) to 2 (Páez, 2020).
REVISTA DE LA UNIVERSIDAD DEL ZULIA. 3ª época. Año 13 N° 36, 2022
D. P. Guerrero-Cuasapaz et al. // Analysis of the structural behavior of flat and circular 222-240
DOI: http://dx.doi.org/10.46925//rdluz.36.15
227
(1)

(2)
Where "R" is the radius of the circumference of the self-supporting roof; "L" is the distance
of the roof; "F" is the arrow on the cover, and "c" is a percentage that depends on the aesthetic
or architectural environment; this value fluctuates between 0 to 50 % (Proingcol, 2021). For
this research, a percentage of 20 % was used to generate a more economical roof, since the
greater the deflection, the greater the length of the steel sheet, consequently, the greater
weight of the steel.
In the flat self-supporting roof, a minimum slope indicated in the previous topics of this
manuscript was used, as a consequence, the maximum height applied was 6.70 m.
1.3. Loads and load combinations applied to self-supporting roofs: flat and circular
In this research, the loads applied to the self-supporting roofs were dead, live, hailstone,
wind, and earthquake, i.e., vertical and horizontal loads.
The dead load corresponds to the own weight of the structural elements such as truss-
type perimeter columns and beams and the so-called self-supporting steel sheets. Regarding the
live load, it had a value of 70 kg/m² considered as an overload to carry out maintenance of the
roof. The hailstone load on the circular self-supporting roof considered as a reference the slopes
generated by the roof itself, less than 15 % and less than 5 %, with the application of loads
directed in the sense of gravity, which were 50 kg/m² and 100 kg/m² respectively; while in the
flat self-supporting roof a value of 50 kg/m² was applied, being a representative value of a
uniform accumulation of 5 cm of hailstone (NEC Cargas no sísmicas, 2014). The latter points
out that the hailstone load application values are different due to the shape of the roofs and the
possible accumulation of hailstone.
For the application of wind load in the analyzed structures, it is evident that it is due to
the configuration presented in figure 1, i.e., a flat roof on one side and a circular roof on the other.
It can be seen in figure 3 how the application diagrams are different.
REVISTA DE LA UNIVERSIDAD DEL ZULIA. 3ª época. Año 13 N° 36, 2022
D. P. Guerrero-Cuasapaz et al. // Analysis of the structural behavior of flat and circular 222-240
DOI: http://dx.doi.org/10.46925//rdluz.36.15
228
(a)
(b)
Figure 3. Wind load application diagrams on self-supporting roofs: a) flat, b) circular.
Because of the latter, tables 3 and 4 indicate the parameters used for the application of
the wind load and table 5 shows the horizontal force due to the earthquake in industrial
buildings.
Table 3. Parameters for wind load application on flat self-supporting roof.
Length
Cover
height
C1
C2
Vb
W.P.
L.P.
(m)
(m)
(km/h)
(kg/m²)
(kg/m²)
20
7.66
0.880
1.63
66.53
10.64
21.28
C1: height correction coefficient, C2: height environment coefficient, Vb: corrected wind speed,
W.P.: windward pressure, L.P.: leeward pressure.
Table 4. Parameters for wind load application on circular self-supporting roof.
Length
Cover
height
C1
C2
Vb
W.P.
L.P.
(m)
(m)
(km/h)
(kg/m²)
(kg/m²)
20
10.30
0.902
1.91
68.20
30.50
26.15
C1: height correction coefficient, C2: height environment coefficient, Vb: corrected wind speed,
W.P.: windward pressure, L.P.: leeward pressure.
In this paper, analysis and design of the self-supporting roofs were carried out using the
method by load and resistance factor design with its acronym LRFD, in which the resistance or
failure condition is considered and where the applied service loads of the structure is factored
REVISTA DE LA UNIVERSIDAD DEL ZULIA. 3ª época. Año 13 N° 36, 2022
D. P. Guerrero-Cuasapaz et al. // Analysis of the structural behavior of flat and circular 222-240
DOI: http://dx.doi.org/10.46925//rdluz.36.15
229
and also the resistance of the material is reduced. This factored load must be less than or equal
to the reduced resistance (Loachamin et al., 2021); for this purpose, a computational package
that works with finite elements was used (SAP 2000, 2021).
Table 5. Parameters to define the basal shear used in self-supporting roofs: flat and circular.
Description
Parameter
Value
Importance factor
I
1.00
Seismic force reduction factor
R
3.00
Seismic zone
-
V
Zone acceleration factor
Z
0.40
Spectral amplification ratio
ƞ
2.48
Soil type
-
C
Fa site fact
Fa
1.20
Fd site fact
Fd
1.11
Fs inelastic behavior factor of the soil
Fs
1.11
Project geographic location factor
r
1.00
Limit period in T=To
To (s)
0.103
Limit period in T=Tc
Tc (s)
0.565
Limit period in T=Tl
Tl (s)
2.664
Plant irregularity factor
P
1.00
Elevation irregularity factor
E
1.00
Basal shear with respect to reactive load
V
0.3968
The load combinations used in this research are those detailed in equations 3 to 10 (NEC
Cargas no sísmicas, 2014).
Where "D" is the dead load; "L" corresponds to live load; "Lr" is the live roof load, "S"
represents the hail load; "W" corresponds to the wind load; "E" represents the load due to
earthquake.
After the analysis and design (SAP 2000, 2021), the structure was discretized and only the
steel sheets with the cross-section indicated in figure 2 were taken into consideration for self-
supporting roofs: flat and circular, in which the computational tool for analysis and simulation
by finite elements (ANSYS, 2021) was used, in which the self-supporting roofs were modeled.
REVISTA DE LA UNIVERSIDAD DEL ZULIA. 3ª época. Año 13 N° 36, 2022
D. P. Guerrero-Cuasapaz et al. // Analysis of the structural behavior of flat and circular 222-240
DOI: http://dx.doi.org/10.46925//rdluz.36.15
230
The modeling of 9 steel sheets was proposed for the circular self-supporting roof, while 15 steel
sheets were used in the roof in the flat for modeling, as indicated in figures 4 and 5.

(3)
  󰇛 󰇜
(4)
 󰇛 󰇜
󰇛 󰇛 󰇜󰇜
(5)
 󰇛 󰇜
󰇛 󰇜
(6)
 󰇛 󰇜 󰇛 󰇜

(7)
 󰇛 󰇜
(8)
 󰇛 󰇜 󰇛 󰇜
(9)
(10)
Figure 4. Steel sheets for circular self-supporting roof.
REVISTA DE LA UNIVERSIDAD DEL ZULIA. 3ª época. Año 13 N° 36, 2022
D. P. Guerrero-Cuasapaz et al. // Analysis of the structural behavior of flat and circular 222-240
DOI: http://dx.doi.org/10.46925//rdluz.36.15
231
Figure 5. Steel sheets for flat self-supporting roof.
Regarding the analysis of the simulation by finite elements (ANSYS, 2021), in the self-
supporting roofs: flat and circular for the discretization of the steel sheets, surface bodies were
used due to the small thicknesses indicated in table 1, i.e., these elements have their nodes
located at their vertices. This alternative was chosen due to the less computational time
generated in it; these surface bodies that were used were triangular and quadrilateral elements
(Lee, 2019), as seen in figures 6 and 7.
Figure 6. Discretization of flat self-supporting roof.
REVISTA DE LA UNIVERSIDAD DEL ZULIA. 3ª época. Año 13 N° 36, 2022
D. P. Guerrero-Cuasapaz et al. // Analysis of the structural behavior of flat and circular 222-240
DOI: http://dx.doi.org/10.46925//rdluz.36.15
232
Figure 7. Discretization of circular self-supporting roof.
The supports that were applied in the circular self-supporting roof were an edge
condition without displacements as can be seen in figure 8 but allowing rotations; in addition,
the interaction that existed between the steel sheets with the clamping plates were taken into
account. This is a vertical displacement restriction on the surfaces that are in direct contact with
the support plate, and the same edge condition was applied in the flat self-supporting roof (Páez,
2020; Pilamunga, 2021).
(a)
(b)
Figure 8. Edge condition in self-supporting roofs: a) circular, b) flat.
REVISTA DE LA UNIVERSIDAD DEL ZULIA. 3ª época. Año 13 N° 36, 2022
D. P. Guerrero-Cuasapaz et al. // Analysis of the structural behavior of flat and circular 222-240
DOI: http://dx.doi.org/10.46925//rdluz.36.15
233
2. Results and Discussions
Due to the complexity of the cross-sections of the steel sheets used for flat and circular
self-supporting roofs, an equivalent thickness was used as shown in table 6; these were modeled
in a computer package (SAP 2000, 2021), which served as starting point to analyze the complete
structure, consisting of structural elements such as columns, beams, and steel sheets.
Table 6. Equivalent thickness of self-supporting roofs.
Roof type
Equivalent thickness
(mm)
Flat
60.91
Circular
50.70
Analysis and design of the elements that make up the industrial buildings were carried
out using steel sheets for flat and circular roofs; tables 7 to 10 show axial loads and displacements
for certain load combinations indicated in the equations described in the previous section of this
manuscript. The reactions were taken from the zone with the largest tributary area; additionally,
the displacements were extracted in the upper part of the left and right column, both for the flat
and circular self-supporting roof. Table 11 shows the behavior of the structures concerning
vibration modes and periods (SAP 2000, 2021), for both self-supporting roofs.
Table 7. Flat self-supporting roof reactions.
Reactions (kgf)
Load pattern
D
L
D+L
1.2D+1.6L
Left column
1646.70
262.91
1909.61
2396.70
Right column
1656.86
269.29
1926.14
2419.08
In the tables presented above, it is evident that concerning the reactions for a
combination of dead load plus live load, the circular self-supporting roof transmitted greater
load, and this corresponds to 2.24 times the value of the load transmitted by the self-supporting
REVISTA DE LA UNIVERSIDAD DEL ZULIA. 3ª época. Año 13 N° 36, 2022
D. P. Guerrero-Cuasapaz et al. // Analysis of the structural behavior of flat and circular 222-240
DOI: http://dx.doi.org/10.46925//rdluz.36.15
234
roof in the flat; consequently, structural elements such as columns of the circular self-supporting
roof were found with higher axial loads.
Table 8. Displacements of flat self-supporting roof.
Displacements (mm)
Load pattern
Left column
Right column
Center of span
Seismic X
Seismic
Y
Seismic X
Seismic
Y
D
D+L
Direction X
11.81837
0.02099
11.81232
0.02174
-3.24299
-3.88444
Direction Y
0.01579
4.81941
0.02903
3.1696
-0.00217
-0.00229
Direction Z
0.03891
0.13525
0.0831
0.08181
-54.0214
-64.61017
Table 9. Circular self-supporting roof reactions.
Reactions (kgf)
Load pattern
D
L
D+L
1.2D+1.6L
Left column
845.97
3466.26
4312.25
6561.20
Right column
846.00
3466.64
4312.64
6561.82
Table 10. Displacements of circular self-supporting roof.
Displacements (mm)
Load pattern
Left column
Right column
Center of span
Seismic X
Seismic
Y
Seismic X
Seismic
Y
D
D+L
Direction X
10.14669
0.62355
10.14891
-0.56252
-0.00169
-0.01378
Direction Y
0.01279
1.10895
0.01278
1.10295
0.0007009
0.00348
Direction Z
-0.06678
0.06323
0.6676
-0.06251
-6.4048
-34.6591
Table 11. Vibration modes and periods in self-supporting roofs: flat and circular.
Flat
cover
Circular
cover
Mode
Period (s)
Period (s)
1
0.419204
0.322233
2
0.34656
0.314963
3
0.218914
0.243651
REVISTA DE LA UNIVERSIDAD DEL ZULIA. 3ª época. Año 13 N° 36, 2022
D. P. Guerrero-Cuasapaz et al. // Analysis of the structural behavior of flat and circular 222-240
DOI: http://dx.doi.org/10.46925//rdluz.36.15
235
On the other hand, about the displacements under the same combination described in the
previous paragraph, it was found that the displacement in the direction of gravity for the
circular self-supporting roof corresponds to 53.64 % of the value found for the flat self-
supporting roof; consequently, the circular roof has a lower deflection located in the center of
the span.
Regarding the seismic behavior of industrial buildings, it was observed that the vibration
modes and periods of each of the analyzed structures comply with the provisions of the
Ecuadorian Construction Standard in the chapter corresponding to seismic danger, which
indicates that the fundamental period of vibration corresponds to an estimate of the value of
the period of the structure, which allows finding the horizontal forces due to earthquakes
applied to the structure (NEC Peligro sísmico, 2014), applying equation 11.
(11)
Where "T" is the period of vibration of the structure, "Ct" is the coefficient that depends
on the type of structure. For this investigation a value of 0.073 was taken, which represents a
steel structure with bracing. Additionally, as a consequence of this value, the coefficient α was
considered with a value of 0.75 and in turn this depends on the type of structure, hn is the
maximum height of the structure measured from the base in meters. If the value obtained from
the period found with equation 11 is increased by 30 %, this value constitutes the period of
vibration calculated analytically according to (NEC Peligro sísmico, 2014); therefore, the period
of vibration found with a modal analysis (SAP 2000, 2021) should not exceed the calculated
analytically, as can be seen in table 12.
Table 12. Calculated vibration period of self-supporting roofs: flat and circular.
Roof type
Tma
Ta
(s)
(s)
Flat
0.4192
0.4368
Circular
0.3222
0.5456
Tma: vibration period of modal analysis, Ta: vibration period analytically calculated.
REVISTA DE LA UNIVERSIDAD DEL ZULIA. 3ª época. Año 13 N° 36, 2022
D. P. Guerrero-Cuasapaz et al. // Analysis of the structural behavior of flat and circular 222-240
DOI: http://dx.doi.org/10.46925//rdluz.36.15
236
Analyzing tables 11 and 12 it is observed that the period found by the modal analysis
corresponds to a lower value than that calculated analytically, consequently, both self-
supporting roofs comply with what is indicated in the Ecuadorian Construction
Standard,seismic danger chapter.
Table 13 shows the inelastic drifts in the X and Y directions. It can be seen that the drifts
obtained from the structural analysis did not exceed the value of the maximum inelastic drift
corresponding to 0.02 (NEC Peligro sísmico, 2014), calculated as indicated in equation 12.
  
(12)
Where iis the maximum inelastic drift, “R” corresponds to the response reduction
factor and e” corresponds to the relation between displacement and height.
Table 13. Inelastic drifts of self-supporting roofs.
Roof type
x
y
i
Flat
0.004109
0.001559
0.02
Circular
0.002907
0.000883
0.02
x: inelastic drift in direction x”, y: inelastic drift in direction “y”, i: maximum inelastic drift.
Another very important piece of data within the field of design and construction which
directly affects the cost of steel corresponds to the weight index of the structure over the area of
the industrial buildings, as can be seen in table 14. The index of the circular self-supporting roof
is less than the flat roof, i.e., the total weight in the circular self-supporting roof corresponds to
56 % of the corresponding value in the flat self-supporting roof.
Table 14. Weight index on self-supporting roof area: flat and circular.
Roof type
Steel sheet
weight
Beams and columns
weight
Total weight
(kg/m²)
(kg/m²)
(kg/m²)
Flat
21.85
8.76
30.61
Circular
11.00
6.16
17.16
REVISTA DE LA UNIVERSIDAD DEL ZULIA. 3ª época. Año 13 N° 36, 2022
D. P. Guerrero-Cuasapaz et al. // Analysis of the structural behavior of flat and circular 222-240
DOI: http://dx.doi.org/10.46925//rdluz.36.15
237
Regarding the modeling used (ANSYS, 2021), and considering figures 6 and 7, in table 15
it is possible to observe the number of elements and nodes in which the self-supporting roofs
were discretized, in which it could be seen that the number of nodes and elements of the flat
self-supporting roof corresponds to a value of 50 % of that obtained for a circular self-supporting
roof.
Table 15. Number of nodes and elements in self-supporting roofs: flat and circular.
Roof type
Steel sheet
quantity
Node
quantity
Elements
quantity
Flat
15
869164
853834
Circular
9
1706600
1985400
In the finite element simulation process, in order to comply with what is related to the
stresses and displacements obtained in the industrial buildings, the thickness of the steel sheets
that made up the self-supporting roofs was increased, as indicated in table 16, being the
allowable limit value in creep 342 MPa and the allowable limit displacement of 100 mm. It was
observed that stresses and displacements on both roofs are fully met with these parameters;
additionally, it was observed that the greatest stresses were presented at the supports of each
roof as shown in figure 9, i.e., at the ends; while the maximum displacements were presented in
the center of the span of each roof as shown in figure 10.
Table 16. Maximum stresses and displacements in self-supporting roofs.
Roof
type
Initial
thickness
Final
thickness
Maximum
stress
Maximum
displacement
(mm)
(mm)
(MPa)
(mm)
Flat
1.55
1.95
330.19
89.273
Circular
0.61
0.76
272.42
12.785
REVISTA DE LA UNIVERSIDAD DEL ZULIA. 3ª época. Año 13 N° 36, 2022
D. P. Guerrero-Cuasapaz et al. // Analysis of the structural behavior of flat and circular 222-240
DOI: http://dx.doi.org/10.46925//rdluz.36.15
238
(a)
(b)
Figure 9. Maximum stresses in self-supporting roofs: a) flat, b) circular.
(a)
(b)
Figure 10. Maximum displacements in self-supporting roofs: a) flat, b) circular.
Conclusions
In this research, when analyzing the structures corresponding to self-supporting roofs:
flat and circular with the characteristics described in this manuscript it can be concluded that
the circular self-supporting roof provides better benefits in terms of structural behavior, i.e.,
both the efforts and displacements generated by the application of horizontal and vertical
REVISTA DE LA UNIVERSIDAD DEL ZULIA. 3ª época. Año 13 N° 36, 2022
D. P. Guerrero-Cuasapaz et al. // Analysis of the structural behavior of flat and circular 222-240
DOI: http://dx.doi.org/10.46925//rdluz.36.15
239
stresses easily comply with the parameters established within the Ecuadorian Construction
Standard.
After the analysis and structural design, it is very important to mention that the weight
of the steel sheets that make up the circular self-supporting roof was less in the construction
area than the sheets that make up the flat self-supporting roof; consequently, this factor will
greatly influence in deciding to choose any of the alternatives (flat and circular) for the
application in a certain project.
References
Açoport (2021). Açoport Telhas Autoportantes. http://acoport.com.br/telhas-autoportantes/dados-
tecnicos/
AISC (2016). Specification for Structural Steel Buildings Supersedes the Specification for Structural Steel
Buildings dated and all previous versions Approved by the Committee on Specifications.
AISI (2016). North American Specification for the Design of Cold-Formed Steel Structural Membe (N.o 2016).
1-505. https://cfsei.memberclicks.net/assets/docs/publications/aisi-standards/aisi s100-16 s100-
16-c_e_s.pdf
ANSYS (2021). Ansys Academic | Simulation Software for Educators, Researchers and Students.
https://www.ansys.com/academic
Arnedo Pena, A. (2016). Naves industriales con acero. Sener, 97. www.sener.es
ASTM A653 (2020). ASTM A653 / A653M - 20 Standard Specification for Steel Sheet, Zinc-Coated
(Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process.
https://www.astm.org/Standards/A653.htm
Cuichán Velasco, A. S., & Escuela Politécnica Nacional (2016). Análisis y diseño de una nave industrial
y sus respectivas fosas dentro del taller «Chiriyacu» para ferrocarriles del Ecuador Empresa Pública F.E.E.P.
Durma (2016). Las cubiertas autoportantes y sus características - Estructuras Metálicas.
https://www.durmametal.com/las-cubiertas-autoportantes-caracteristicas/
Fernández Madrid, J. (1998). La cubierta plana. Tectónica: monografías de arquitectura, tecnología y
construcción, 6, 1-16.
Lee, H. H. (2019). Finite element simulation with ANSYS Workbench 2019 (SDC Publications (ed.);
Primera ed).
REVISTA DE LA UNIVERSIDAD DEL ZULIA. 3ª época. Año 13 N° 36, 2022
D. P. Guerrero-Cuasapaz et al. // Analysis of the structural behavior of flat and circular 222-240
DOI: http://dx.doi.org/10.46925//rdluz.36.15
240
Loachamin Chano, D. F., Freire Luna, A. E., Guerrero Cuasapaz, D. P., & Guerrón Figueroa, M.
B. (2021). Análisis técnico-económico de naves industriales mediante interpolación no lineal de
Lagrange. Revista Técnica de la Facultad de Ingeniería Universidad Del Zulia, 44(2), 1-15.
https://doi.org/https://doi.org/10.22209/rt.v44n2a05
Nápoles Padrón, E., González Carbonell, R., & Olivares Díaz, E. (2015). Una introducción al alisis
por elementos finitos: aplicaciones y ejemplos (E. Piñero de Laosa (ed.); Primera). Editorial
Universitaria. https://www.researchgate.net/publication/283151622
NEC Cargas no sísmicas (2014). Cargas nosmicas. Norma Ecuatoriana de la Construcción, 1-44.
NEC Peligro sísmico (2014). Peligro sísmico. Norma Ecuatoriana de la Construcción, 1-148.
Páez Redrován, C. D., & Universidad Politécnica Salesiana (2020). Método de elementos finitos
aplicado a cubiertas autoportantes tipo circular. En Tesis. Universidad Politécnica Salesiana.
Pilamunga Guallpa, J. L., & Universidad Politécnica Salesiana (2021). Simulación de una
cubierta plana autoportante y su conexión con las vigas laterales mediante la aplicación de
elementos finitos. En Tesis. Universidad Policnica Salesiana.
Proingcol (2021). Cubiertas autoportantes Proing LTDA | Manlift & Cubiertas autoportantes.
https://proingcol.co/cubiertas-autoportantes/
Ruiz Sancho, J. M. (2003). Geometria análitica del plano y del espacio (Anaya Educación (ed.); 2003.a
ed.).
Sanxing (2021). Yingkou Sanxing Roll Forming Machine Co., Ltd. - Building Material Machinery.
https://yk-sanxing.en.alibaba.com/
SAP 2000. (2021). SAP2000 | STRUCTURAL ANALYSIS AND DESIGN.
https://www.csiamerica.com/products/sap2000
Soria Carrasco, H. D., & Escuela Politécnica Nacional (2020). Análisis tecno económico entre galpones
con cubiertas autoportantes y cubiertas a dos aguas con luces de 20 metros fabricadas en acero estructural.
Escuela Policnica Nacional.
Vásquez, M., & López, E. (2001). El método de los elementos finitos aplicado al análisis estructural
(Noela-Madrid (ed.); Primera).
https://www.academia.edu/38827344/El_método_de_los_Elementos_Finitos_aplicado_al_anális
is_estructural_Manuel_Vázquez_Eloísa_López